Search results for "virtual point detector"

showing 2 items of 2 documents

Virtual point detector: Application to coincidence-summing correction in gamma-ray spectrometry

2009

The use of an efficiency transfer method based on the virtual point detector approximation to evaluate coincidence-summing correction values for point and volume sources was examined. The method was validated by means of a comparison with experimental efficiency determinations.

PhysicsRadiationbusiness.industrySettore ING-IND/20 - Misure E Strumentazione NucleariPoint detectorGamma-ray spectrometryCoincidence-summingCoincidenceOpticsVolume (thermodynamics)Point (geometry)Virtual point detectorbusinessGamma ray spectrometry
researchProduct

Valutazione di efficienze fotoelettriche per uno scintillatore LaBr3(Ce) tramite un approccio Virtual Point Detector

2019

L’impiego di uno scintillatore a Bromuro di Lantanio, LaBr3(Ce), come strumento di misura della attività (o concentrazione) in un dato campione, richiede la valutazione delle efficienze fotoelettriche o la conoscenza di una corrispondente curva di calibrazione. Oltre ai consueti metodi basati sull’impiego di sorgenti calibrate aventi la stessa forma e composizione del campione in esame, o metodi Monte Carlo, uno strumento rapido di valutazione delle efficienze può essere rappresentato dall'applicazione della semplificazione “Virtual Point Detector” (VPD), ovvero con il rilevatore assunto equivalente a un punto virtuale all’interno del cristallo dove si può considerare avvengano tutte le int…

efficienzevirtual point detectorSettore ING-IND/20 - Misure E Strumentazione NucleariSpettrometria gammascintillatore LaBr3(Ce)
researchProduct